SC6280 80 °C Low-Temp Cure Conductive Silver — Single-Component, High Bond, Low Resistivity
QUALITY CONTROL100% Lab Tested
DISPENSING SPECNordson Syringe
OUTER PACKAGINGVacuum-Sealed
PACKAGING SPEC5/10cc/syringe
Permeating the silicon matrix from the unseen

SC6280 80 °C Low-Temp Cure Conductive Silver — Single-Component, High Bond, Low Resistivity

Conductive silver series. Single-component, low-temp cure, 60 °C minimum. High bond strength, chip-grade, 3.1–4.5 GPa tensile modulus. Dispensable & printable. 500 thermal cycles (−40 to 125 °C): 54% shear retention.

Typical Application

Heat-sensitive components, chips, low-temperature sensors and medical modules — bonding, fixation, thermal and electrical conduction.

Technical Specifications
Shear Strength
18 MPa
Tg
120 °C
Cure Condition
80 °C / 60 min
Viscosity @ 25 °C
15000 mPa·s
* Multiple specifications are available for this series
SCITEO Rigorous Standards: Qualified under GJB 150 environmental reliability testing by Zhenhua, CETC, and CAC, delivering mission-critical reliability.

Engineered as high-reliability domestic qualified alternatives for semiconductor and defense manufacturing clusters across Shanghai Zhangjiang, Xi'an, Chengdu, and Wuxi.

SCITEO R&D ARCHIVE

Specifications Don't Match Your Operating Conditions?

Only the baseline series is shown here. SCITEO's undisclosed archive holds formulations engineered for extreme environments. Contact us — our application engineers will match you precisely.

Contact Below
APPLICATION FIELDS

High Reliability Scenarios

Core positioning and partial application demonstration of this product under complex operating conditions.

SCITEO conductive silver adhesive for wafer bonding process electrical conductive bonding

Conductive Wafer Bonding

SCITEO conductive silver adhesive appearance and packaging display

Product & Packaging Display

SCITEO conductive silver adhesive for power module bonding, electrical and thermal conductance

Power Module Bonding

FAQ & ENGINEERING ANSWERS

Application Engineer FAQ

A structured brief from SCITEO covering physical properties, application standards, and related specifications.

Q

Is cure temperature fixed?

A

No. Cure follows Arrhenius kinetics: higher temperature accelerates the reaction and shortens the required time. SC6280 curing at 120 °C takes about half the time of 80 °C — convert by equivalent degree of cure.

Q

Minimum cure temp? How does it differ from standard conductive adhesives?

A

The series activates from 60 °C. Rare for a low-temperature system, its Tg exceeds the cure temperature — reaching 120 °C, above most standard conductive adhesives, and suits complex thermal cycling.

Engineering Support

Request Technical Documentation or Consult an Application Engineer

Receive product documentation and customized formulations. Please provide accurate information for verification.